Medical Camera Module Principle generally consists of a controller, lifting platform, camera, cable, crawler, and lighting. Essence It can be configured with a blind zone rotating lens or axial fixing color lens, the camera camera and recorded the pipeline status, and other detection devices can be carried inside the pipeline.

Medical Camera Module Principle

(1) Crack. When the beam is exposed to the surface of the detected object, the black or bright lines are observed, and under a certain magnification, the lines are determined as a crack when the lines have irregular edges. When the crack is wide, the measurement of the measurement of the probe can be bent.

(2) Peel. When the beam is parallel, there is a shadow behind the protruding part; if the angle of the beam is changed, the raised part of the surface and the surrounding detecting objects are observed, and the peel is judged.

(3) Line and scratches. Under the beam, the continuous long line of the surface is observed, and it is determined as a pull line.

(4) The concave pits are raised. When the beam is irradiated at a certain angle, it is connected to the surrounding border, and there is no boundary line. There are shadows near the light source, and there are bright shadows from the light source, which is a pit. When the beam is irradiated at a certain angle, it is connected to the surrounding border, and there is no boundary line. The raised part is bright, and the shadow behind it is a pit. When the concave pit is deeper or raised, the measurement line of the probe can be measured.

(5) Spots. During the beams, the smooth and uneven surface of the objects that was different from the surrounding objects was observed as spots.

(6) Corrosion. Under the beam, the block and dot -shaped surface are observed, and the slightly unevenness is corrosion at a certain magnification.

(7) Not welded. Observed the obvious boundary between the melting metal and the mother material and the weld layer.

(8) Welding leakage. When the beam is irradiated at a certain angle, it is observed that it is connected to the melting metal.

(9) Surgery. When the beam is irradiated at any angle, there are extra objects other than the structure of the surrounding objects that are basically different.

(10) Pretending defects. Observe the structural phenomenon that does not meet the technical conditions of the pattern during detection.

(11) Size measurement. When there is a requirement, measure the size of the probe can be measured.